Burnflash

This item was filled under [ Shoretel ]
Issue: You need to Burnflash as switch.
Scenario: You need to Burnflash a switch and you are not sure of the Burnflash utility function.

Resolution: The burnflash utility is used to manually update the switch with the current version firmware compatible with the ShoreWare server software.

When you install a new switch, ShoreTel’s TMS service is set up to detect the switch’s firmware version and automatically upgrade your hardware to the latest version.  For instances that require manual firmware upgrade, you could use Burnflash utility to manually upgrade switch firmware.  Please refer to Maintenance Guide for detail instruction.

From the server command line, enter the burnflash command in this format:

x:\Program Files\Shoreline Communications\ShoreWareServer>burnflash -s <IP of the switch>

You can follow any responses to this entry through the RSS 2.0 feed. You can leave a response, or trackback from your own site.

Leave a Comment